Product Details
Chilled Water Vertical Expose Floor standing Fan Coil UnitProduct Details1)Low noise.
2)Easy installation.
3)Special design of air filter.
4)Air flows: 340 to 2380m3/h.
5)Cooling capacity range: 1.8 to 12.6kW.
6)Power supply: 220V, 50HZ, and 1pH depends on the different country.
7)Used for: Industry,hotel,commercial bulding,etc.
8)Function: cooling only,cooling and heating.
9)Test condition for rated refrigerating output of fan coil unit.
Product Series1. Horizontal concealed FCU
2. Horizontal exposed FCU
3. Cassette FCU
4. Split FCU
5. Vertical exposed FCU
6. Vertical concealed FCU
7. Ceiling, floor FCU
Product Parameter
Vertical Expose Fan Coil Unit |
Model HLC~ |
34VE |
51VE |
68VE |
85VE |
102VE |
136VE |
170VE |
204VE |
238VE |
Air flow (m 3 /h) |
High speed |
340 |
510 |
680 |
850 |
1020 |
1360 |
1700 |
2040 |
2380 |
Medium speed |
255 |
383 |
510 |
638 |
765 |
1020 |
1275 |
1530 |
1785 |
Low speed |
170 |
255 |
340 |
425 |
510 |
680 |
850 |
1020 |
1190 |
Cooling capacity |
High |
W |
1800 |
2700 |
3600 |
4500 |
5400 |
7200 |
9000 |
10800 |
12600 |
BTU |
6143 |
9215 |
12287 |
15359 |
18430 |
24574 |
30717 |
36860 |
43004 |
Medium |
W |
1620 |
2440 |
3290 |
4120 |
4850 |
6550 |
8190 |
9730 |
11580 |
BTU |
5529 |
8328 |
11229 |
14062 |
16553 |
22355 |
27952 |
33208 |
39523 |
Low |
W |
1310 |
2010 |
2650 |
3320 |
3900 |
5300 |
6610 |
7860 |
9350 |
BTU |
4471 |
6860 |
9044 |
11331 |
13311 |
18089 |
22560 |
26826 |
31912 |
Heating capacity |
High |
W |
2700 |
4050 |
5400 |
6750 |
8100 |
10800 |
13500 |
16200 |
18900 |
BTU |
9215 |
13823 |
18430 |
23038 |
27645 |
36860 |
46076 |
55291 |
64506 |
Medium |
W |
2350 |
3520 |
4530 |
6040 |
6850 |
9260 |
11740 |
14140 |
16360 |
BTU |
8021 |
12014 |
15461 |
20615 |
23379 |
31604 |
40069 |
48260 |
55837 |
Low |
W |
1620 |
2470 |
3130 |
4170 |
4740 |
6500 |
8180 |
9710 |
11290 |
BTU |
5529 |
8430 |
10683 |
14232 |
16178 |
22185 |
27918 |
33140 |
38533 |
Cooling water temperature |
7°C-12°C |
Hot water temperature |
40°C-60°C |
Power supply |
AC220V/50Hz |
Heat Exchanger |
Type |
copper pipes covered into aluminum fins, fin pitch 2.2mm |
Water supply kg/h |
324 |
482 |
655 |
814 |
936 |
1278 |
1602 |
1915 |
2178 |
Water resistance kPa |
30 |
30 |
30 |
30 |
40 |
40 |
40 |
40 |
50 |
Working pressure |
1.6MPa |
Low static pressure FCU |
Input power w |
37 |
52 |
62 |
76 |
96 |
134 |
152 |
189 |
228 |
Motor power w |
10 |
16 |
20 |
25 |
30 |
20×2 |
25×2 |
30×2 |
40×2 |
High static pressure FCU |
Static pressrue 30Pa |
Input power w |
44 |
59 |
72 |
87 |
108 |
156 |
174 |
212 |
253 |
Motor power w |
12 |
20 |
25 |
30 |
40 |
25×2 |
30×2 |
40×2 |
50×2 |
Static pressure 50Pa |
Input power w |
49 |
66 |
84 |
100 |
118 |
174 |
210 |
250 |
300 |
Motor power w |
16 |
25 |
30 |
40 |
50 |
30×2 |
40×2 |
50×2 |
60×2 |
Fan motor quantity |
1 |
2 |
2 |
2 |
2 |
3 |
4 |
4 |
4 |
Noise dB(A) |
Low static pressure |
≤37 |
≤39 |
≤41 |
≤43 |
≤45 |
≤46 |
≤48 |
≤50 |
≤52 |
High static pressure 30Pa |
≤40 |
≤42 |
≤44 |
≤46 |
≤47 |
≤48 |
≤50 |
≤52 |
≤54 |
High static pressure 50Pa |
≤42 |
≤44 |
≤46 |
≤47 |
≤49 |
≤50 |
≤52 |
≤54 |
≤56 |
Pipe |
Inlet/outlet water pipe |
3/4 "internal thread |
Condensation water pipe |
external thread |
Dimension |
L mm |
1000 |
1000 |
1200 |
1300 |
1400 |
1600 |
1900 |
2100 |
2100 |
W mm |
270 |
270 |
270 |
270 |
270 |
270 |
270 |
270 |
270 |
H mm |
645 |
645 |
645 |
645 |
645 |
645 |
645 |
645 |
645 |
20GP container loading quantity |
189 |
189 |
158 |
146 |
135 |
118 |
100 |
90 |
90 |
40GP container loading quantity |
373 |
373 |
311 |
287 |
267 |
233 |
196 |
178 |
178 |
Main materials |
Aluminium thickness:0.014mm, Copper tube thickless:0.35mm, Galvanized sheet: 1mm, Packing: Carton |
Note: |
1. Cooling: Indoors DB 27°C,WB 19.5°C;Chilled water inlet/outlet temp. 12°C/7°C. |
2. Heating: Indoors DB WB 21°C, heating water inlet&outlet temperature 60°C/50°C; |
3.The noise level based on: background noise 11.5Db(A) semi-anechoic room. |
4. Water resitance refers to that of rated water flow volume; |
5. Input power refers to that of High speed air flow; |
6. Above parameters are for your reference to model choice of FCU with cooling and heating; Heating energy of one row is 40% of three rows'; Low |
static pressure air flow volume loss: 10%, high static pressure air flow volume loss: 20%. |
Product Show
Delivery & Payment1. Packing: Standard Plywood Package.
2. Delivery Day: 25 days after deposit is confirmed.
3. Delivery term: CIF,FOB or CNF EX-Work are welcomed.
4. Payment term: T/T, 30% deposit, 70% before delivery; Or 100% Irrevocable non-transferred L/C at sight.
5. Warranty: Warranty for 12 months from the date of shipment from the factory, whichever comes first.
6. Validity: 20 days.
7. Payment currency: USD or EX-Work CNY.
FAQ Q: What information do you need to provide in order to get a quotation?
A: Generally, for fan coil unit we need to know the Cooling Capacity, Air Flow, Power Supply and Order Quantity etc in order to suggest the suitable fan coil unit models and for providing the quotation.
Q: Can I have a samples for testing before ordering products?
A: Yes, you can.
We sincerely suggest that customers should have some samples of required fans for testing because the truly performance of fans can be fully demonstrated after testing is conducted.
Q: What is the warranty of products?
A: For 1 year warranty. Free to amend and change the parts due to quality reasons in warranty year.